Habotest HT5910 Digital Meter, RCD Tester, LOOP, AUTORAMP, LCD Display, Red

Habotest
135,22 EUR

Habotest HT5910 digital tester for RCD, LOOP and AUTORAMP checks in electrical installations. Measures AC voltage up to 440V and loop resistance up to 2000Ω, and supports testing residual currents of 10mA, 30mA, 100mA, 300mA and 500mA. Features an LCD screen, memory for 100 data sets, USB 2.0 and a CAT III 600V safety rating.

 

In stock
Stock limit
Add to cart
Product Code: HT5910 Do you need help? 0725129997
Add to wishlist Request information
  • Description
  • Reviews (0)

Habotest HT5910 RCD and LOOP Tester, AUTORAMP, LCD, Memory for 100 Data Sets

Habotest HT5910 is a digital measuring instrument for testing RCDs, checking loop resistance and analysing electrical installations. The tester allows checks of trip time, trip current, touch voltage, loop resistance and AC voltage, making it suitable for electrical inspection, maintenance and diagnostic work.

RCD Tester LOOP Test AUTORAMP Function Memory for 100 Data Sets CAT III 600V

Product Description

The Habotest HT5910 digital tester is a professional instrument for checking residual current devices (RCDs) and testing loop resistance in electrical installations. It is suitable for electricians, installers, maintenance technicians and specialists carrying out technical checks in homes, commercial premises, electrical distribution boards and low-voltage installations.

The HT5910 model measures AC voltage from 0 to 440V, loop resistance from 0.1Ω to 2000Ω and touch voltage from 0 to 99.9V. The tester supports rated residual currents of 10mA, 30mA, 100mA, 300mA and 500mA, providing flexibility for checking several types of residual current protection.

RCD, LOOP and AUTORAMP Testing

The dedicated RCD test, LOOP test and AUTORAMP functions help check the operation of residual current devices and electrical circuits. The instrument allows testing at current multipliers of x0.5, x1 and x5, as well as selection of a phase angle of 0° or 180°, for test scenarios adapted to the installation.

LCD Display and Data Storage

The LCD screen clearly displays measured values, providing quick access to information while working. Habotest HT5910 can save up to 100 data sets, and the USB 2.0 interface allows information to be transferred for documentation and subsequent analysis.

Recommended for checking RCDs, measuring loop resistance, testing touch voltage and inspecting electrical installations during servicing, maintenance and technical checks.

Habotest HT5910 Technical Specifications

Product Type Digital RCD / LOOP / AUTORAMP tester
Model Habotest HT5910
Trip Time 1 × IΔN 300ms / 500ms; 5 × IΔN 40ms / 150ms, ±3ms
Trip Current (0.2–1.1) IΔN, ±0.1 IΔN
Touch Voltage 0–99.9V, ±10% + 0.2V
AC Voltage 0–440V AC, ±3% + 3V
Frequency DC, 45–65Hz, ±1Hz
LOOP Resistance 0.1–2000Ω, ±10% + 0.2d
RL Test Current 0.51 IΔN, ±10% + 10d
Test Current Multipliers x0.5, x1, x5
IΔN Current Levels 10mA, 30mA, 100mA, 300mA, 500mA
Phase Angle 0° or 180°
Display LCD screen
Data Storage 100 data sets
Interface USB 2.0
Power Supply 6 AA 1.5V batteries, not included
Dimensions 180 × 140 × 65 mm
Weight Approx. 95 g
Safety Rating EN61010-1 / CAT III 600V

Recommended Applications

  • Testing residual current devices (RCDs).
  • Checking trip time and trip current.
  • Measuring LOOP resistance in electrical installations.
  • Checking touch voltage.
  • Testing residential and commercial electrical installations.
  • Electrical servicing, maintenance and diagnostic work.
  • Documenting measurements using internal memory and USB 2.0.

Frequently Asked Questions About the Habotest HT5910 RCD and LOOP Tester

What is Habotest HT5910?
Habotest HT5910 is a digital measuring instrument for testing RCDs, checking loop resistance and analysing electrical installations.
What is the Habotest HT5910 tester used for?
The tester is used to check residual current devices (RCDs), measure loop resistance, check touch voltage and test electrical installations.
What does the RCD function do?
The RCD function allows residual current devices to be checked, including their trip time and trip current.
What does the LOOP function do?
The LOOP function is used to measure loop resistance in an electrical circuit, an important check when analysing protective electrical installations.
What is AUTORAMP?
AUTORAMP is a progressive testing function that helps determine the current at which an RCD trips.
What is the AC voltage range?
Habotest HT5910 can measure AC voltage from 0 to 440V.
What is the loop resistance range?
The tester measures loop resistance within the 0.1Ω–2000Ω range.
What residual currents can it test?
Habotest HT5910 allows selection of IΔN currents of 10mA, 30mA, 100mA, 300mA and 500mA.
Does it have memory for measurements?
Yes. The tester can store up to 100 data sets, useful for successive checks and technical documentation.
Does it have a USB interface?
Yes. Habotest HT5910 includes a USB 2.0 interface for data transfer.
What batteries does it use?
The instrument operates on 6 AA 1.5V batteries. Batteries are not included.
Is it suitable for professional use?
Yes. Habotest HT5910 is suitable for electricians, installers, maintenance technicians and specialists who carry out checks on electrical installations.
See more
Product compliance information
If you want to express your opinion about this product you can add a review.

The review was sent successfully.

Compara produse

You must add at least one product to compare products.

Was added to wishlist!

Was removed from wishlist!