Taxnele TXSA-40 AC Surge Protective Device, 2P, L+N, Uc 275V, Imax 40kA, In 20kA, Up ≤ 2.0kV, SPD, DIN Rail Mounting.

TAXNELE
new
25,80 EUR

Taxnele TXSA-40 AC surge protective device, 2P L+N, Uc 275V, Imax 40kA, In 20kA, Up ≤ 2.0kV, SPD for DIN rail mounting.

In stock
Stock limit
Add to cart
Product Code: TXSA-40KA 2P Do you need help? 0725129997
Add to wishlist Request information
  • Description
  • Reviews (0)
Electrical & Automation • Surge Protective Devices (SPD)

Taxnele TXSA-40 AC Surge Protective Device, 2P L+N, 40kA, DIN Rail Mounting

Taxnele TXSA-40 is an AC surge protective device (SPD) designed to protect single-phase electrical installations against transient overvoltages and voltage impulses. The device features a 2P L+N configuration, Uc 275V, Imax 40kA, In 20kA, Up ≤ 2.0kV and DIN rail mounting within the electrical distribution board.

SPD for AC Networks 2P L+N Imax 40kA In 20kA DIN Rail Mounting

Product Description

The Taxnele TXSA-40 AC surge protective device is an SPD designed to protect low-voltage electrical installations against voltage spikes. It is installed on a DIN rail within the electrical distribution board and helps limit transient overvoltages that may affect equipment connected to the mains.

The model features a 2P L+N configuration, making it suitable for single-phase electrical installations with protection on the phase and neutral conductors. Its main ratings are Uc 275V, Imax 40kA, In 20kA and Up ≤ 2.0kV, which are useful characteristics for integration into residential, commercial or technical distribution boards.

With its modular DIN rail mounting, Taxnele TXSA-40 can be integrated alongside circuit breakers, residual current devices and other protective equipment. It is suitable for circuits requiring additional protection against voltage impulses within a correctly designed and installed electrical system.

The surge protective device must be installed by an authorised electrician or qualified personnel in accordance with the distribution board wiring diagram, applicable technical standards and the manufacturer's instructions.
SPD

Surge Protection

The device limits transient overvoltages in the AC network and helps protect connected electrical equipment.

40kA

Maximum Current of 40kA

The maximum discharge current Imax of 40kA enables the device to handle surge impulses within the limits specified for this model.

DIN

DIN Rail Mounting

The modular construction allows installation on a DIN rail in standard electrical distribution boards by qualified personnel.

Main Benefits

  • Protection for single-phase L+N electrical installations.
  • Limits voltage impulses within the electrical distribution board.
  • Maximum discharge current Imax of 40kA.
  • Nominal discharge current In of 20kA.
  • Voltage protection level Up ≤ 2.0kV.
  • Simple integration into electrical distribution boards with DIN rails.
  • Suitable for residential, commercial and technical applications.

Recommended Applications

  • Single-phase electrical distribution boards.
  • Houses and flats.
  • Commercial premises and offices.
  • Garages, workshops and technical areas.
  • Circuits containing sensitive electrical equipment.
  • Installations where additional protection against voltage spikes is required.

Taxnele TXSA-40 Technical Specifications

Product Type AC surge protective device / SPD
Brand Taxnele
Model TXSA-40
Commercial Name TXSA-40KA / TXSA-40, 40kA
Number of Poles 2P
Terminal Configuration L + N
Maximum Continuous Operating Voltage Uc 275V
Nominal Discharge Current In 20kA
Maximum Discharge Current Imax 40kA
Voltage Protection Level Up ≤ 2.0kV
Network Type AC, single-phase
Mounting DIN rail, within an electrical distribution board
Use Protection against transient overvoltages and voltage impulses
Applications Homes, commercial premises, offices, workshops, garages and technical areas
Category Electrical & Automation
Subcategory Electrical Protection / Surge Protective Devices (SPD)

Frequently Asked Questions About the Taxnele TXSA-40 Surge Protective Device

What is Taxnele TXSA-40?

Taxnele TXSA-40 is an AC surge protective device (SPD) used to limit transient overvoltages and voltage impulses in single-phase electrical installations.

Where is this surge protective device installed?

The device is installed on a DIN rail within the electrical distribution board, in accordance with the wiring diagram and installation instructions.

Which installations is the 2P L+N model suitable for?

The 2P L+N model is suitable for single-phase electrical installations with phase and neutral conductors in residential, commercial or technical applications.

What is its maximum discharge current?

The Taxnele TXSA-40 model has a maximum discharge current Imax of 40kA and a nominal discharge current In of 20kA.

What is its voltage protection level?

The voltage protection level is Up ≤ 2.0kV, according to the model's specifications.

Can anyone install it?

No. Installation must be carried out by an authorised electrician or qualified personnel in accordance with applicable electrical standards and the distribution board wiring diagram.

40kA SPD Protection for Single-Phase Electrical Installations

Taxnele TXSA-40 offers a compact solution for protecting electrical installations against transient overvoltages, with DIN rail mounting, a 2P L+N configuration, Uc 275V, Imax 40kA, In 20kA and a protection level Up ≤ 2.0kV.

See more
Product compliance information
If you want to express your opinion about this product you can add a review.

The review was sent successfully.

Compara produse

You must add at least one product to compare products.

Was added to wishlist!

Was removed from wishlist!